Connected Box: the permanent hotel module
Same base unit and same fit-out, without the off-grid pack. Connected to the site's water, power and drainage, it targets year-round operation with lower running costs and maximum comfort.
Request a quote
Technical specifications
| Connections | Mains water, 230 V power (30 A breaker), sewer or existing on-site septic system |
|---|---|
| Sanitary | Standard flush toilet |
| Hot water | 50 L water heater |
| Everything else | Identical to the Off-Grid Box (dimensions, bed, heat pump, smart lock, telemetry) |
| Weight | 4.2 t |
| Option | 2.8 kWp solar pack for self-consumption |
The rest of the data sheet matches the Off-Grid Box: dimensions, bed, heat pump, smart lock, telemetry.
Operating costs
Limited electricity use
Reversible heat pump, LED lighting and 100 mm insulation on walls and roof.
No front-desk staff
Remote operation: automatic access codes, smart lock and telemetry.
Simplified maintenance
A single service hatch grouping connections and service components.
Who it is for
- Campsites and residential leisure parks
- Extensions to existing hotels
- Sites already serviced
Regulatory framework
It depends on the land, the length of the installation and whether the unit stays mobile or becomes fixed. In France, an installation of less than three months is exempt from formalities in most cases (article R.421-5 of the planning code); beyond that, a prior declaration or a permit may be required depending on floor area and zoning. We review your situation with you before any order.